Oxymax for Windows v5.71
Updated January 18th, 2024 Posted by Karson
This release contains the following changes:
Support for the latest minimitter telemetry receivers the ER4500
Notes on Upgrading
Upgrading Oxymax for Windows v4.40 (~December 2009) or later simply involves uninstalling the existing version and running "setup.exe" from the new version. The configuration files necessary for each system are preserved on the removal of version of Oxymax 4.40 or greater and will automatically be used after the installation of a later version.
Users wishing to upgrade from a version of Oxymax for Windows older than 4.40 will simply need to move their configuration files (*.ini and *.exp) from their old installation directory (C:\Program Files\OxymaxWinV#.##\Config\ ) to the new installation directory (C:\Program Files\Oxymax\Config\ ). For questions about updating Oxymax or if you need to replace your configuration files.
Oxymax for Windows v5.69
Updated June 30th, 2023 Posted by Carl
This release contains the following changes:
Changed sensor routines for backwards compatibility with H2, H2S, and CH4 sensors.
Oxymax for Windows v5.68
Updated July 28, 2022 Posted by Ron
This release contains the following changes:
Improved error checking for non-metabolic systems.
Oxymax for Windows v5.66
Updated Oct 07, 2021 Posted by Ron
This release contains the following changes:
Enviromental Controller Export Bug Fix
Oxymax for Windows v5.65
Updated Oct 07, 2021 Posted by Ron
This release contains the following changes:
Oxymax for Windows v5.64
Updated Jan 15, 2021 Posted by Ron
This release contains the following changes:
Native 4 sensor support
Efficiency changes in Data Presentation
Oxymax for Windows v5.58
Updated Feb 20, 2020 Posted by Ron
This release contains the following changes:
Updated Sensor support
Calibration Updates
Oxymax for Windows v5.54
Updated Dec 17, 2019 Posted by Ron
This release contains the following changes:
UFC Support
Positional analysis playback
WC Feces measurement Ability
Oxymax for Windows v5.40
Updated Oct 18, 2017 Posted by Ron
This release contains the following changes:
Support for new line of UGS/UGC devices
Ergometric Running Wheel Support
Oxymax for Windows v5.35
Updated Jan 30, 2017 Posted by Dan
This release contains the following changes:
Fixed issue with configuration files that contain unused flow controllers
New body mass monitoring algorithm
General code cleanup
Oxymax for Windows v5.34
Updated Oct 5, 2016 Posted by Dan
This release contains the following changes:
Bout/Event CSV files are now separated by event type
Oxymax for Windows v5.33
Updated Sep 30, 2016 Posted by Dan
This release contains the following improvements and fixes:
Fixed an issue with reading gas sensors on multiple-group SSP systems
Fixed an issue with shading on data graphs
Oxymax for Windows v5.32
Updated Sep 16, 2016 Posted by Dan
This release contains the following improvements and fixes:
Fixed issue tallying Accumulated Feeding data on systems where chambers share a Load Cell Controllers
Fixes an issue initializing and reading Iso-Thermex units
Oxymax for Windows v5.30
Updated Aug 25, 2016 Posted by Dan
This release contains the following improvements and fixes:
Fixed issue reading flow meter on legacy Negative Flow Controllers
Fixed saving feature on Set All Masks on Activity Monitor
Added support for Urine Events on balances and load cells
Oxymax for Windows v5.28
Updated Jul 22, 2016 Posted by Dan
This release contains the following improvements and fixes:
Fixed crashing issue on new OxyVal utility
Fixed issue with Windows Junction flow controllers
Oxymax for Windows v5.27
Updated Jun 17, 2016 Posted by Dan
This release contains the following improvements and fixes:
Fixed minor issue in Treadmill Setup that resulted in software crashes
General code clean up
Oxymax for Windows v5.26
Updated Jun 13, 2016 Posted by Dan
This release contains the following improvements and fixes:
New OxyVal utility
Fixed valve switching issue on Windows-Junction systems
Improved timer on Iso-Thermex Temperature utility
Oxymax for Windows v5.25
Updated Jun 2, 2016 Posted by Dan
This release contains the following improvements and fixes:
Support for new PL202-E balances
New balance utility in Oxymax and CI Diagnostic
Oxymax for Windows v5.24
Updated May 2, 2016 Posted by Dan
This release contains the following improvements and fixes:
Finally resolved VDM Over/Underpump issue preventing channels 5-8 on any VDM from checking out properly
Oxymax for Windows v5.23
Updated April 29, 2016 Posted by Dan
This release contains the following improvements and fixes:
Cleaned up graph setup panel
Fixed issue with VDM calibrations in CID
Fixed crashing issue with old FlowMax units in CID
Fixed issue not scanning beams from some old Opto-M3 units
Added ability to launch CID from Startup page
Oxymax for Windows v5.22
Updated April 15, 2016 Posted by Dan
This release contains the following improvements and fixes:
Added Events for Volumetric Drinking and Running Wheels
Renamed "Consumption Events" as "Events" to include feeding, drinking, and running wheel events together in one place
Improved initialization for Iso-Thermex and DTD units
Fixed issue not-logging some GPC/VDM readings
Fixed purge issue with multiple VDM units
Fixed erroneous Underpump warnings
Fixed false-positive on missing Opto units during initialization
Fixed Reservoir Empty messages for older VDM units
Oxymax for Windows v5.21
Updated April 11, 2016 Posted by Dan
This is a rapid release to fix a deal-breaker issue on some systems
Fixed issue that makes v5.20 unworkable for systems without calorimeters
Oxymax for Windows v5.20
Updated March 28, 2016 Posted by Dan
This release of Oxymax is a must-update for users with v5.03-v5.17 and contains the following changes and improvements:
Dropped support for Windows XP/Vista
New, simpler installer
Fixed VDM Purge issue introduced in v5.19
Improved communication/resources management
General code cleanup
Oxymax for Windows v5.19
Updated March 21, 2016 Posted by Dan
This release of Oxymax is a must-update for users with v5.03-v5.17 and contains the following changes and improvements:
Dropped support for Windows XP/Vista
New, simpler installer
Reworked Running Wheels from the ground up
Simplified VDM pump error conditions and setup
Slowed down communication to free up resources
Increased OxyDataAcq priority for both processes and threads
Fixed issues with valve switching on Expansion Interface units introduced in v5.03
General code cleanup
Oxymax for Windows v5.18
Updated February 17, 2016 Posted by Dan
This release of Oxymax is a must-update for users with v5.03-v5.17 and contains the following changes and improvements:
Fixed "OxyDataAcq has stopped responding" crash
Fixed Urine accumulation sign issue
General code cleanup
Oxymax for Windows v5.17
Updated February 4, 2016 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Fixed critical math error in VDM counting data; this is a required update for Oxymax users v5.13-v5.16
Fixed bug opening older CDTA files (pre-v4.10)
Fixed initializing legacy analog devices
Improved Load Cell refill measuring
Changes to communication timers to improve stability
Changes to Zirconia Reference log
Oxymax for Windows v5.16
Updated January 14, 2016 Posted by Dan
This release of Oxymax contains the following changes and improvements:
New Oxymax Utility and Calibration procedures
Fixed activity initialization issue introduced in v5.03
Fixed bug where backup location wasn't being saved to INI
Change Zircomax reference voltage procedure to always use incoming voltages
Added warning message for Windows XP/Vista users regarding the impending removal of support
Added warning message about saving data in Program Files for all users
Added support for Load Cell drinking bouts
Renamed "Feeding Events" to "Consumption Events" to accommodate new drinking events
General tidying up of codebase
Oxymax for Windows v5.15
Updated December 1, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Fixes progress bar bug when loading larger experiment files
Fixes support for older Opto-M3 activity monitors
Oxymax for Windows v5.14
Updated October 26, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Improvements referencing on Zircomax Oxygen Sensors
Oxymax for Windows v5.12
Updated July 16, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Fixed display issue in Load Cell Utility for some systems
Fixed future-scheduling issue for Temperature profiles on Environmental Controllers
Oxymax for Windows v5.11
Updated May 26, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Added initial support for Load Cell Drinking Control
Fixed Startup.ini packaging for CLAX
Added "Save Events" to Help menu for exporting System Logs
Added ability to check for software updates
Oxymax for Windows v5.10
Updated Apr 13, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Improved algorithms for feeding and drinking data from Load Cells
Added support for more masking for position monitoring
Enabled activity channel masking with the Activity Monitor utility
Oxymax for Windows v5.09
Updated Feb 17, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Additional calibration settings for Load Cells
Oxymax for Windows v5.08
Updated Jan 27, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Fixed a minor issue involving reading Load Cell configuration info out of config files
Oxymax for Windows v5.07
Updated Jan 5, 2015 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Fixed issue with Load Cell drinking where only the first bout would be registered
Fixed communication issues with older Opto-M3 activity monitors
Added VDM controls to the Experiment window so utilities can be accessed mid-experiment
Oxymax for Windows v5.06
Updated Dec 10, 2014 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Adjusted settings for Load Cells
Oxymax for Windows v5.05
Updated Oct 18, 2014 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Handful of small CI Diagnostic improvements
More preliminary USSP support
Fixed communication issue for MiniMitters; this update is required for MiniMitter users already on v5.0+
Fixed issue with reading fresh air flow on Windows Junction systems
Added Demo Mode support for Environmental Controller units
Added ability to set Environmental Controller temperature to a "manual" mode
Oxymax for Windows v5.04
Updated Sep 8, 2014 Posted by Dan
This release should be considered a must update for users of v5.03; v5.04 fixes an intermittent inability to zero Automatic CO2 sensors depending on the size/complexity of the Oxyma system. The issue is resolved in v5.04. This release of Oxymax contains the following changes and improvements:
Major improvements to communication speed
Removed FDTA feeding files as the BDTA Feeding Bout files are smaller in size and contain more information
Oxymax and CI Diagnostic are now signed with security certificates to simplify Windows settings
Includes drivers for CI-Bus Hub boxes
Improved Load Cell data and taring
Fixes CO2 zeroing issue introduced in v4.95/v4.96
Lots of small performance increases
Fixed CO2 zeroing issue for some systems
Improved Waste Freezing performance
Oxymax for Windows v5.02
Updated Jul 9, 2014 Posted by Dan
This release of Oxymax contains the following changes and improvements:
Added support for the new Environmental Controller
Fixed small number of bugs
Improvements to CI Diagnostic controls
Oxymax for Windows v5.01
Updated Jun 11, 2014 Posted by Dan
This is major release of Oxymax with a significant number of optimizations and new features. The new manual that accompanies this version should be considered a 'must-read'.
Changed in this version of Oxymax for Windows :
Replaced Splash screen with Quickstart window
Reworked Hardware Status Window to contain more information
Increased flow controller limit from 8 to 32 units per system
Improved communication to all components of Pull-Ventilation systems
Improved Feed Control timing and resource use removing an entire process from Oxymax
Improved warning logging
Improved responsiveness of all 'Loading' screens
Added support for new model of FlowMax Pull device
Added support for new Opto-M4 Activity/Position Monitor products
Added Activity Monitor for real-time position viewing
Added Position Analysis to filter and export position data for XY-axis activity systems
Added automatic reconnect for temporarily lost serial communication
Added support for Load Cell based drinking
Fixed Sample Pressure display issue on multi-group Oxymax systems
Fixed CI-Bus Serial Interface communication issues for partially functioning systems
Fixed Treadmill Controller warm-up speed issues for successive experiments
Simplified configuration information for all flow controllers
Cleaned up warning/information message boxes program-wide
Updated MDI background to Pantone's "Dazzling Blue " (18-3949)
Removed option to turn off fresh air when closing Oxymax; fresh air always remains on
Dropped support for Windows-Junction based systems with multiple flow controllers
Oxymax for Windows v4.94
Updated October 21, 2013 Posted by Dan
Changed in this version of Oxymax for Windows :
Added support for second generation Urine Chillers
Changed Oxymax Initialization to re-engage fresh air pumps
Oxymax for Windows v4.93
Updated September 4, 2013 Posted by Dan
Changed in this version of Oxymax for Windows :
Added Treadmill Controller "Speed" and "Odometer" to regular and high-resolution data
Added support for the Treadmill Shock Detector
Added sample "Pressure" to Metabolic data (where applicable; diagnostically relevant figure, not relevant to animal data)
Added Running Wheels to Sleep Detection utility
Oxymax for Windows v4.92
Updated June 13, 2013 Posted by Dan
Changed in this version of Oxymax for Windows :
Added initial Multi-FlowMax support
Fixed Timeline issue for FAST Systems
Improved buffering for FlowMax units
Oxymax for Windows v4.91
Updated January 22, 2013 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed an issue where high-resolution activity settings wouldn't display for some Running Wheel customers
Oxymax for Windows v4.90
Updated December 14, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Lots of refactoring for performance increase
Added Running Wheels to the High-Resolution Activity (.ADTA) data files
Added per-experiment Zircnia Reference logging
Added ability to use 0.0 m/min for treadmill controllers
Increased limit on saving Treadmill Schedule steps from ~30 to ~500
Fixed issue where Error Logs were not being saved in copy-locations
Fixed some Sleep Analysis overflow issues
Oxymax for Windows v4.87
Updated October 18, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed duplicate data file extension issue for some users
Fixed communication issues with 2010-2011 generation USB-to-Serial adapters
Modified Waiting and Hardware Status window aesthetics
Added "Release Treadmill Control" menu option
Increased Help Document capacity from 10 to 15
Oxymax for Windows v4.86
Updated September 28, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Resolved random communication issues with feeding balances
Fixed "Close Feeders" button in Experiment menu
Separate "Refill Feeders" into utilities for Balances and Load Cells for customers with both
Improved initialization of CLAMS devices on startup
Oxymax for Windows v4.85
Updated August 28, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Added Feed Control reversal options for individual channels via "FREV" property on Balances and Load Cells
Modified Open/Close All menu options in Oxymax to use
Fixed bug where Feeding Bouts and Body Weight records would be logged for disabled channels
Oxymax for Windows v4.84
Updated August 24, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed high-resolution activity data collection on double-channel activity systems
Fixed high-resolution feeding data on mixed feeder-type systems
Removed load cell debugging routines mistakenly built into previous versions
Added additional configuration settings into the saved data
Oxymax for Windows v4.83
Updated August 14, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Reformatted "Flow" column on Experiment Setup for some complicated systems
Fixed load cell urine exporting issue
Improved error trapping in Oxymax experiment loops
Oxymax for Windows v4.82
Updated July, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Improved intialization of SampleMax units
Improved Load Cell initialization
Fixed Opto-M3 initialization
Fixed FlowMax reset issue on Oxymax Utility
Oxymax for Windows v4.80
Updated June 25, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed forced extension for .CDTA files on Setup window
Fixed "dirty flag" bug for linked-feeding in Feed Control
Fixed timestamp issue on FDTA files
Adjusted Treadmill Control timing
Oxymax for Windows v4.79
Updated June 13, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed "ghost" MDTA file issue
Fixed flow slider on Oxymax Utility
Oxymax for Windows v4.78
Updated April 25, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed a bug causing exported Body Mass files to all contain the same data
Added support for multi-group systems with multiple SampleMax's per group
Removed the ability to start a new experiment immediately after the conclusion of an experiment to prevent the unintentional overwriting of data
Improved Feed Control timing/logic
Improved Iso-Thermex initialization performance
Added ability to adjust Reference Flow tracking speed on Negative Flow Controllers
Added support for Negative Flow Controllers that regulate pressure as well as vacuum
Expanded Zirconia temperatuer tolerances
Oxymax for Windows v4.75
Updated February 20, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Added support for the new software-controlled Urine Chiller
Added the ability to save and re-use Treadmill Profiles
Fixed telemetry heart rate filter to work outside metabolic systems
Fixed a bug preventing serial COM ports indexed higher than '9' from being recognized
Updated manual to reflect changes
Oxymax for Windows v4.74
Updated January 30, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Redesigned Scan Utility in CI Diagnostic v1.60
Initial support for software-controller Urine Chiller
Added "rail error" detection for CO2 sensors that return maximum values during an interval
Added additional error codes
Fixed error coloring for cells in the data-table to show individual failures rather than group-wide problems
Improved communication to Load Cells
Oxymax for Windows v4.73
Updated January 10, 2012 Posted by Dan
Changed in this version of Oxymax for Windows :
Fixed a bug in the Subject Info table where values would "ghost" if focus on the grid was lost without committing the new value
Fixed a bug where subject mass was always exported to CSV's as "grams" regardless of user selection
Fixed a bug where Negative Flow Controller flow's failed to convert from mL to L if communication latency got too high
Changed the "Date" field on saved Feeding Bout data to use the date of the Start of the bout rather than the date the entry was recorded
Improved communication to Load Cell devices
Oxymax for Windows v4.72
Updated December 5, 2011 Posted by Dan
Changed in this version of Oxymax for Windows :
Corrected a small timing error involving analog Expansion-based systems without pressure correction introduced in v4.70
Oxymax for Windows v4.71
Updated November 16, 2011 Posted by Dan
Changed in this version of Oxymax for Windows :
Improved back-vacuum management on Negative Flow Paramagnetic systems
Corrected a multiplication versus division issue in Linked feeding; software now performs as described in Software Manual
Oxymax for Windows v4.70
Updated October 27, 2011 Posted by Dan
Changed in this version of Oxymax for Windows :
Added back-vacuum regulator control to Sample Conditioning Units for Paramagnetic Oxygen Sensors
Modified Treadmill Control timer
Oxymax for Windows v4.69
Updated September 30, 2011 Posted by Dan
Fixed in this version of Oxymax for Windows :
Fixed an issue displaying percentage of time asleep in the Sleep Analysis utility
Fixed an issue saving important Feeding and Activity settings into data files for future analysis
Disabled "Refresh" buttons on Hardware Status window while an experiment is running
Oxymax for Windows v4.68
Updated September 19, 2011 Posted by Dan
Fixed in this version of Oxymax for Windows :
Corrected display units for CO2 calibration for some models of CO2 sensor to "%" from "V"
Fixed flow recording problem for systems where groups share fresh-air flow controllers
Fixed LED flashing issue for Sample Conditioning Units on Fuel Cell and Paramagnetic Oxymax systems
Fixed Experiment Setup issue for systems with more flow-channels than available channels in the system
Oxymax for Windows v4.66
Updated August 12, 2011 Posted by Dan
Fixed in this version of Oxymax for Windows :
Fixed flow setting bug for Eco-Oxymax (single channel) users
Oxymax for Windows v4.65
Updated July 29, 2011 Posted by Dan
New to this version of Oxymax for Windows :
Fixed tab-switching stability issue exacerbated by changed to v4.62
Installer now comes with drivers for commonly used USB-to-Serial converters
Oxymax for Windows v4.64
Updated July 18, 2011 Posted by Dan
New to this version of Oxymax for Windows :
Fixed quirky flow selection on Experment Setup screen
Fixed updating flows to all chambers on a single flow controller for Experiment Configurations
Bugs will not have caused an error with data collection; only unexpected behavior during setup.
Oxymax for Windows v4.63
Updated July 6, 2011 Posted by Dan
New to this version of Oxymax for Windows :
Automatically saves Feed Control settings with experiment data
Fixed ability to open data files created in versions of Oxymax older than v4.10
Fixed display bug in Feed Control settings
Oxymax for Windows v4.62
Updated June 20, 2011 Posted by Dan
Version 4.61 was an internal beta that was not released to the general public. Oxymax v4.62 contains the new features of v4.61 with improved stability and better documentation.
New to this version of Oxymax for Windows :
Redesigned "Experiment Setup" screen with better usability and stability
Improved intialization routines for Iso-Thermex and Mini-Mitter systems
Improved error handling for Dual Tube Drier devices on start up
Improved stability in tab switching while experiments are running
Added Environmental Enclosure manual to help documents
Fixed bug preventing Environmental Monitor data from being saved to the "Backup" data location
Fixed pump control support for dual-head pump Sample Conditioning Units
Fixed activity setting display issue in Experiment Properties
Fixed channel setting editor for VDM's in Experiment Properties
Updated Software Manual for new features
Oxymax for Windows v4.60
Updated March 15, 2011 Posted by Dan
New to this version of Oxymax for Windows :
Added support for additional load cell models
Added urine-monitoring load cells to the refill utility
Relaxed restrictions on operating temperature of the Zirconia Oxygen Sensor
New edition of the Oxymax Software Manual that reflects changes to the interface
Oxymax for Windows v4.59
Updated February 25, 2011 Posted by Dan
New to this version of Oxymax for Windows :
Complete support for load-cell based urine monitoring
Fixed bug that cause intermittent communication to load cells for some customers
Oxymax for Windows v4.58
Updated January 18, 2011 Posted by Dan
New to this version of Oxymax for Windows :
Added telemetry heart rate filter to Experiment Properties
Fixed bug for systems with balances and load cells introduced with high-resolution load cell feeding support
The Software Manual has been updated to reflect changes to the interface
Oxymax for Windows v4.57
Updated December 22, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Modified Oxymax to require administrative rights to run; this eliminates issues that arise in "legacy" software related to UAC Directory Virtualization (see the manual for details).
Added more back-end Zirconia calibration options
Fixed Treadmill Controller display issue
Oxymax for Windows v4.56
Updated December 2, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Improved Zirconia O2 sensor calibration
Improved MiniMitter diagnostics and sampling
Oxymax for Windows v4.55
Updated November 25, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Improved feeding bout determinations for balances
Modified CO2 range checks for non-standard Oxymax systems
Fixed E-Mitter serial assignment alignment issue introduced in v4.40 for systems with 13+ E-Mitter receivers
Fixed delimitation error in displaying Feed Control statuses for Load Cells introduced in v4.53
Fixed port selection for Negative Flow Zirconia O2 sensor calibration
Updated CI-Diagnostic Utility to version 1.50: Additional diagnostic tools for Zircomax, initial support for Opto-M4 activity monitor
Oxymax for Windows v4.54
Updated September 29, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Fixed delimitation error in displaying Feed Control statuses introduced in v4.53
Oxymax for Windows v4.53
Updated September 27, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Improved status recording for load cells
Improved response time of Feed Control events
Added Feed Control status to feeders with controllers
Added quick access to "View Only" Oxymax that bypasses hardware initialization for reviewing Oxymax data
Fixed Sample Pump initialization for some Ref/Cal port reference setups
Fixed Feeding Bout initialization in the event of an error when writing backup data files
Fixed schedule update issue for Treadmill Controller
Removed outdated "Effective Mass" calculation
Updated edition of the Software Manual
Oxymax for Windows v4.52
Updated August 31, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Added "Refill Feeders" utility for Load Cell feeders
Fixed CH4 calibration port selection problem
Fixed high-resolution Load Cell feeding data timestamp issue
Fixed bout recording bug for rapidly occurring feeding bouts
Fixed bug introduced in v4.51 where bout criteria always reset to defaults on experiment start
Updated edition of the Software Manual
Oxymax for Windows v4.51
Updated July 12, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Fixed energy expenditure (Heat) unit export bug
Fixed SSP-based reference port selection for multi-group systems
Fixed drift adjustment on balance tare
Added Hydrogen Sensor support
Updated all calibration procedure forms
Changed Negative Flow Controller valving logic to prevent pump dead-heading
Changed default sampled port on 'New Experiment' to Reference instead of Channel 1
Changed 'Other' calibration settle/measure times to 90/30s from 60/20s
Oxymax for Windows v4.50
Updated June 11, 2010 Posted by Dan
New to this version of Oxymax for Windows :
Added support for Feed Control using Load Cell Feeders
Added High-Frequency measuring of Load Cell Feeders
Added "On Experiment Conclusion" option for Feed Control
Removed configuration instructions from /Config folder; embedded in executable
Modified experiment initialization for variable loading times
Added Treadmill Control logging